Mechanical Integrity Test Online Database

In August 2016 we copied a large portion of the Office of Oil and Gas online database for Mechanical Integrity Tests. This database is no longer available online so we are presenting our copy here.

This MIT database copy needs to be used with caution. There are errors sometimes in the databases. We copied databases by county and didn't copy all the counties with UIC wells. Just because a well doesn't appear on the database copy, doesn't mean that information wasn't available at that time. This table includes data for disposal and secondary recovery wells.

Wells are identified by API number in an abbreviated form (without the state, 47-, prefix). The table is searchable by API number (in part or whole) or any other sequence of letters or numbers.

 

API MIT Test Date MIT Test Comments
001-00561 12/10/2012 Annulus pressure passed  
001-00561 10/29/2012 Annulus pressure passed  
001-00561 10/8/2012 Casing/tubing pressure passed  
001-00561 10/27/2011 Annulus pressure passed  
001-00777 4/21/1993 Casing/tubing pressure passed  
015-00051 1/28/1994 Casing/tubing pressure passed  
015-00095 4/17/1995 Casing/tubing pressure passed  
015-00698 10/28/2011 Annulus pressure passed  
015-00698 9/4/2008 Casing/tubing pressure passed  
015-00698 3/2/1993 Casing/tubing pressure passed  
015-00867 2/26/1993 Casing/tubing pressure passed  
015-00874 8/11/1995 Other passed  
015-00883 3/26/1993 Casing/tubing pressure passed  
015-00892 1/13/1994 Casing/tubing pressure passed  
015-00899 9/16/1992 Casing/tubing pressure passed  
015-00899 9/11/1992 Casing/tubing pressure failed  
015-00926 8/25/1999 Other passed  
015-00933 7/22/1999 Other passed  
015-00933 4/16/1992 Annulus pressure passed  
015-00943 8/25/1999 Other passed  
015-01017 3/24/2014 Annulus method passed  
015-01017 12/15/2008 Annulus method passed  
015-01017 6/7/1998 Casing/tubing pressure passed  
015-01017 10/10/1996 Casing/tubing pressure passed  
015-01107 9/23/2008 Casing/tubing pressure passed  
015-01107 8/11/1994 Casing/tubing pressure passed  
015-01109 9/24/1993 Casing/tubing pressure passed  
015-01128 9/18/2008 Casing/tubing pressure passed  
015-01128 8/9/1995 Other passed  
015-01132 9/19/2014 Annulus method passed  
015-01132 8/13/2008 Casing/tubing pressure passed  
015-01132 8/11/1994 Casing/tubing pressure passed  
015-01133 6/6/2011 Annulus method passed  
015-01166 8/10/2011 Annulus method passed  
015-01166 9/12/1998 Other passed  
015-01170 8/10/2011 Annulus method passed  
015-01170 7/22/1999 Other passed  
015-01172 8/3/1999 Other passed  
015-01172 8/2/1999 Annulus method passed  
015-01173 8/14/1998 Casing/tubing pressure passed  
015-01173 2/27/1992 Casing/tubing pressure passed  
015-01173 2/7/1992 Annulus pressure failed  
015-01174 9/16/1997 Casing/tubing pressure passed  
015-01176 8/3/1999 Annulus method passed  
015-01177 8/3/1999 Annulus method passed  
015-01184 9/1/1999 Other passed  
015-01185 10/16/1997 Casing/tubing pressure passed  
015-01187 10/28/2011 Annulus pressure passed  
015-01187 7/15/1999 Other passed  
015-01188 7/21/2011 Annulus method passed  
015-01188 7/15/1999 Other passed  
015-01190 8/30/2011 Annulus method passed  
015-01190 7/22/1999 Other passed  
015-01198 12/8/1993 Casing/tubing pressure passed  
015-01219 7/27/1999 Other passed  
015-01220 8/4/1999 Other passed  
015-01221 8/25/1999 Other passed  
015-01223 7/15/1999 Other passed  
015-01226 9/8/2011 Casing/tubing pressure passed  
015-01226 7/22/1999 Other passed  
015-01227 7/22/1999 Other passed  
015-01239 11/17/2011 Annulus pressure passed  
015-01239 8/4/1999 Other passed  
015-01241 7/27/1999 Other passed  
015-01242 10/28/2011 Annulus pressure passed  
015-01242 8/4/1999 Other passed  
015-01243 8/30/2011 Annulus method passed  
015-01243 8/4/1999 Other passed  
015-01249 7/27/1999 Other passed  
015-01250 4/13/1995 Casing/tubing pressure passed  
015-01250 10/25/1994 Annulus pressure failed  
015-01250 4/15/1994 Casing/tubing pressure passed  
015-01251 7/22/1999 Other passed  
015-01273 7/15/1999 Other passed  
015-01306 5/21/1999 Other passed  
015-01307 8/4/1999 Other passed  
015-01310 5/19/1999 Other passed  
015-01429 7/22/1999 Other passed  
015-01468 9/2/1998 Casing/tubing pressure passed  
015-01468 2/15/1993 Casing/tubing pressure passed  
015-01483 9/9/1998 Casing/tubing pressure passed  
015-01485 9/12/1998 Other passed  
015-01507 7/27/1999 Other passed  
015-01507 5/17/1996 Annulus pressure failed  
015-01591 7/27/1999 Other passed  
015-01592 8/3/1999 Other passed  
015-01593 7/27/1999 Other passed  
015-01593 5/11/1994 Casing/tubing pressure passed  
015-01593 4/13/1994 Annulus pressure failed  
015-01593 3/24/1994 Annulus pressure failed  
015-01594 7/27/1999 Other passed  
015-01594 3/24/1994 Annulus pressure failed  
015-01596 8/24/1998 Casing/tubing pressure passed  
015-01596 2/12/1993 Casing/tubing pressure passed  
015-01596 10/4/1992 Annulus pressure failed  
015-01597 8/3/1999 Other passed  
015-01601 3/21/2012 Annulus pressure passed  
015-01602 2/7/2012 Casing/tubing pressure passed  
015-01602 8/5/1999 Other passed  
015-01603 2/21/2012 Casing/tubing pressure passed  
015-01603 9/18/1998 Other passed  
015-01621 9/24/1997 Casing/tubing pressure passed  
015-01626 8/5/1999 Other passed  
015-01626 4/16/1992 Annulus pressure passed  
015-01630 8/3/1999 Other passed  
015-01630 4/16/1992 Annulus pressure passed  
015-01641 8/28/1998 Casing/tubing pressure passed  
015-01641 3/12/1992 Casing/tubing pressure passed  
015-01641 2/28/1992 Annulus pressure failed  
015-01642 9/22/1992 Casing/tubing pressure passed  
015-01642 6/2/1992 Casing/tubing pressure passed  
015-01643 1/6/1998 Casing/tubing pressure passed  
015-01644 7/22/1999 Other passed  
015-01649 9/19/1997 Casing/tubing pressure passed  
015-01651 8/5/1999 Other passed  
015-01652 7/27/1999 Other passed  
015-01653 7/22/1999 Other passed  
015-01654 8/4/1999 Other passed  
015-01655 9/17/1997 Casing/tubing pressure passed  
015-01721 7/22/1999 Other passed  
015-01722 7/22/1999 Other passed  
015-01723 7/22/1999 Other passed  
015-01724 7/22/1999 Other passed  
015-01724 3/10/1994 Casing/tubing pressure passed  
015-01725 7/22/1999 Other passed  
015-01726 7/22/1999 Other passed  
015-01727 7/22/1999 Other passed  
015-01728 7/22/1999 Other passed  
015-01728 4/16/1992 Annulus pressure passed  
015-01783 7/8/2010 Casing/tubing pressure passed  
015-01783 10/28/1997 Casing/tubing pressure passed  
015-01784 10/27/1997 Casing/tubing pressure passed  
015-01793 9/8/2011 Casing/tubing pressure passed  
015-01793 1/20/1998 Casing/tubing pressure passed  
015-01817 8/3/1999 Other passed  
015-01818 8/5/1999 Other passed  
015-01818 5/6/1992 Casing/tubing pressure passed  
015-01819 8/5/1999 Other passed  
015-01819 5/15/1992 Casing/tubing pressure passed  
015-01820 8/3/1999 Other passed  
015-01820 5/5/1992 Casing/tubing pressure passed  
015-01821 11/21/2011 Annulus pressure passed  
015-01821 9/18/1997 Other passed  
015-01823 8/21/1997 Casing/tubing pressure passed  
015-01824 9/2/1997 Casing/tubing pressure passed  
015-01932 8/27/2014 Casing/tubing pressure passed  
015-01932 8/10/1995 Other passed  
015-01933 8/11/1995 Other passed  
015-01934 11/20/1997 Casing/tubing pressure passed  
015-01934 2/25/1992 Annulus pressure passed  
015-01935 8/11/1995 Other passed  
015-01936 8/11/1995 Other passed  
015-01937 10/2/2012 Annulus pressure passed  
015-01937 8/11/1995 Other passed  
015-01941 8/11/1995 Other passed  
015-01942 8/11/1995 Other passed  
015-01943 9/8/1997 Casing/tubing pressure passed  
015-01951 8/11/1995 Other passed  
015-01952 8/10/1995 Other passed  
015-01953 6/23/2011 Annulus method passed  
015-01953 7/26/1995 Other passed  
015-01954 8/10/1995 Other passed  
015-01955 8/10/1995 Other passed  
015-01956 8/10/1995 Other passed  
015-01958 8/11/1995 Other passed  
015-01959 10/3/2012 Annulus pressure passed  
015-01959 8/11/1995 Other passed  
015-01960 8/10/1995 Other passed  
015-02001 8/5/1999 Other passed  
015-02002 8/29/1997 Casing/tubing pressure passed  
015-02024 8/2/1995 Casing/tubing pressure passed  
015-02121 11/12/2008 Casing/tubing pressure passed  
015-02121 8/10/1995 Other passed  
015-02122 8/8/1995 Casing/tubing pressure passed  
015-02124 7/27/1995 Casing/tubing pressure passed  
015-02125 10/5/2012 Annulus pressure passed  
015-02125 8/10/1995 Other passed  
015-02130 9/19/2014 Annulus pressure passed  
015-02130 10/1/2008 Casing/tubing pressure passed  
015-02130 8/11/1995 Other passed  
015-02131 9/19/2014 Annulus method passed  
015-02131 10/15/2008 Casing/tubing pressure passed  
015-02131 8/1/1995 Casing/tubing pressure passed  
015-02132 11/4/2008 Casing/tubing pressure passed  
015-02132 7/28/1995 Casing/tubing pressure passed  
015-02133 9/10/2014 Annulus method passed  
015-02133 10/28/2008 Annulus method passed  
015-02133 7/31/1995 Casing/tubing pressure passed  
015-02134 11/10/2008 Casing/tubing pressure passed  
015-02134 8/7/1995 Casing/tubing pressure passed  
015-02135 8/10/1995 Other passed  
015-02136 8/11/1995 Other passed  
015-02137 8/10/1995 Other passed  
015-02138 7/27/1995 Casing/tubing pressure passed  
015-02139 9/8/2014 Annulus method passed  
015-02139 7/26/1995 Casing/tubing pressure passed  
015-02140 11/19/1997 Casing/tubing pressure passed  
015-02140 2/25/1992 Annulus pressure passed  
015-02141 7/26/1995 Casing/tubing pressure passed  
015-02145 10/7/2008 Casing/tubing pressure passed  
015-02145 8/14/1995 Other passed  
015-02146 9/8/2014 Annulus method passed  
015-02146 10/3/2008 Casing/tubing pressure passed  
015-02146 8/10/1995 Other passed  
015-02147 8/11/1995 Other passed  
015-02148 12/20/2008 Casing/tubing pressure passed  
015-02148 8/10/1995 Other passed  
015-02149 10/22/2008 Casing/tubing pressure passed  
015-02149 8/1/1995 Casing/tubing pressure passed  
015-02150 10/24/2008 Casing/tubing pressure passed  
015-02150 8/1/1995 Casing/tubing pressure passed  
015-02151 9/10/2014 Annulus method passed  
015-02151 10/30/2008 Casing/tubing pressure passed  
015-02151 8/11/1995 Other passed  
015-02157 7/28/1995 Casing/tubing pressure passed  
015-02158 8/27/2014 Casing/tubing pressure passed  
015-02158 8/3/1995 Casing/tubing pressure passed  
015-02159 8/11/1995 Other passed  
015-02167 10/17/2008 Casing/tubing pressure passed  
015-02167 8/11/1995 Other passed  
015-02168 12/9/2011 Casing/tubing pressure passed  
015-02168 1/25/1994 Casing/tubing pressure passed  
015-02213 12/2/2008 Casing/tubing pressure passed  
015-02213 8/9/1994 Casing/tubing pressure passed  
015-02214 7/21/2008 Casing/tubing pressure passed  
015-02214 8/10/1994 Casing/tubing pressure passed  
015-02215 7/23/2008 Annulus pressure passed  
015-02215 8/9/1994 Casing/tubing pressure passed  
015-02216 8/9/1994 Casing/tubing pressure passed  
015-02217 8/11/2008 Casing/tubing pressure passed  
015-02217 8/9/1994 Casing/tubing pressure passed  
015-02218 8/18/2008 Casing/tubing pressure passed  
015-02218 8/11/1994 Casing/tubing pressure passed  
015-02219 8/20/2008 Casing/tubing pressure passed  
015-02219 8/10/1994 Casing/tubing pressure passed  
015-02220 8/4/2008 Casing/tubing pressure passed  
015-02220 8/9/1994 Casing/tubing pressure passed  
015-02224 7/28/2008 Casing/tubing pressure passed  
015-02224 8/8/1994 Casing/tubing pressure passed  
015-02225 8/26/2008 Casing/tubing pressure passed  
015-02225 8/11/1995 Other passed  
015-02226 2/21/2012 Casing/tubing pressure passed  
015-02226 8/11/1994 Casing/tubing pressure passed  
015-02227 9/19/2014 Other failed  
015-02227 7/16/2008 Casing/tubing pressure passed  
015-02227 8/12/1994 Casing/tubing pressure passed  
015-02230 8/11/1994 Casing/tubing pressure passed  
015-02231 8/11/1994 Casing/tubing pressure passed  
015-02237 1/29/2015 Annulus method failed casing head leaked, retest continued to lose pressure, 1655 dropped to 1540 in 25 minutes
015-02237 8/6/2008 Casing/tubing pressure passed  
015-02237 8/8/1994 Casing/tubing pressure passed  
015-02253 9/11/1997 Other passed  
015-02255 7/22/1999 Other passed  
015-02255 6/3/1992 Casing/tubing pressure passed  
015-02255 5/7/1992 Casing/tubing pressure failed  
015-02298 7/21/2011 Annulus pressure passed  
015-02298 10/30/1996 Casing/tubing pressure passed  
015-02299 9/25/1996 Casing/tubing pressure passed  
015-02300 9/20/1996 Casing/tubing pressure passed  
015-02301 9/26/1996 Casing/tubing pressure passed  
015-02302 7/27/1999 Other passed  
015-02303 11/17/2011 Annulus pressure passed  
015-02303 9/11/1996 Casing/tubing pressure passed  
015-02428 8/27/2014 Casing/tubing pressure passed  
015-02428 8/3/1999 Other passed  
015-02428 10/30/1993 Annulus pressure passed  
015-02430 7/22/1999 Other passed  
015-02430 10/27/1993 Annulus pressure passed  
015-02431 7/15/1999 Other passed  
015-02431 10/27/1993 Annulus pressure passed  
015-02432 7/27/1999 Other passed  
015-02432 10/30/1993 Annulus pressure passed  
015-02472 7/14/1994 Other passed  
015-02473 7/19/1994 Other passed  
015-02474 7/14/1994 Other passed  
015-02475 7/22/1999 Other passed  
015-02475 6/2/1993 Casing/tubing pressure passed  
015-02475 10/12/1992 Casing/tubing pressure passed  
015-02493 6/6/2011 Annulus method passed  
015-02497 6/6/2011 Annulus method passed  
015-02497 8/9/1995 Other passed  
015-02498 8/10/2011 Annulus pressure passed  
015-02498 6/15/2011 Annulus pressure failed  
015-02498 8/10/1995 Other passed  
019-00460 5/11/2012 Casing/tubing pressure passed  
019-00460 4/20/2007 Casing/tubing pressure passed Gene Smith and Terry urban witnessed test. nitrogen pressure to 1300 psi for 20 minutes. 0 bleed off.
019-00460 1/22/2002 Casing/tubing pressure passed  
019-00508 1/17/2014 Annulus pressure passed  
019-00508 10/17/2008 Annulus method passed  
019-00510 12/23/2010 Casing/tubing pressure passed  
019-00510 11/8/2006 Casing/tubing pressure passed  
019-00510 11/16/2001 Casing/tubing pressure passed  
019-00510 7/11/1996 Casing/tubing pressure passed  
039-00644 9/30/2014 Annulus pressure passed  
039-00644 7/22/2009 Other passed  
039-00644 8/24/1994 Other passed  
039-00798 6/11/2015 Casing/tubing pressure passed  
039-00798 12/15/2009 Other passed  
039-00798 4/4/1994 Casing/tubing pressure passed  
039-00798 1/14/1994 Casing/tubing pressure passed  
039-00798 9/16/1993 Casing/tubing pressure passed  
039-00798 12/30/1992 Casing/tubing pressure passed  
039-00798 9/30/1992 Casing/tubing pressure passed  
039-00798 6/10/1992 Casing/tubing pressure passed  
039-00798 3/4/1992 Casing/tubing pressure passed  
039-00798 1/2/1992 Casing/tubing pressure passed  
039-01838 10/22/1998 Casing/tubing pressure passed  
039-01838 3/19/1993 Casing/tubing pressure passed  
039-02210 6/17/2015 Annulus method passed conducted cement squeeze 6-8-2015 following failure, CBL/VDL shows overall good bond from 4430-5340'
039-02210 7/21/2010 Annulus method passed Waited for WR-37 Form for approval 
039-02210 9/22/2004 Annulus method passed  
039-02210 1/10/2002 Annulus pressure failed  
039-02210 2/15/2001 Casing/tubing pressure passed  
039-02210 4/10/1997 Casing/tubing pressure passed  
039-02210 5/14/1992 Casing/tubing pressure passed  
039-02262 5/3/2013 Annulus method passed  
039-02262 6/17/2008 Annulus method passed  
039-02262 8/10/2000 Casing/tubing pressure passed  
039-02296 10/31/2012 Annulus pressure passed  
039-02327 5/3/2013 Annulus method passed  
039-02327 6/17/2008 Annulus pressure passed  
039-02327 10/26/2001 Casing/tubing pressure passed  
039-02327 10/10/2001 Annulus method passed  
039-02327 10/31/1996 Casing/tubing pressure passed  
039-02327 1/21/1993 Casing/tubing pressure passed  
039-02327 1/10/1992 Casing/tubing pressure passed  
039-02419 12/20/2013 Annulus pressure passed  
039-02419 5/3/2013 Annulus method failed  
039-02419 6/17/2008 Annulus pressure passed  
039-02419 9/10/2000 Casing/tubing pressure passed  
039-02419 9/1/2000 Casing/tubing pressure passed  
039-02419 7/14/1995 Casing/tubing pressure passed  
039-02517 2/12/1993 Casing/tubing pressure passed  
039-02622 8/9/1995 Casing/tubing pressure passed  
039-02803 6/15/2011 Casing/tubing pressure passed  
039-02803 8/3/2007 Casing/tubing pressure passed  
039-02803 2/27/2002 Annulus pressure passed  
039-02803 8/3/1995 Casing/tubing pressure passed  
039-03409 2/1/2002 Casing/tubing pressure passed  
039-03409 9/5/2001 Annulus method failed  
039-03409 2/15/2001 Casing/tubing pressure passed  
039-03409 2/17/1995 Casing/tubing pressure passed  
039-03409 2/11/1993 Casing/tubing pressure passed  
039-03409 2/14/1992 Casing/tubing pressure passed  
039-03409 1/30/1992 Casing/tubing pressure failed  
039-03754 6/9/2011 Casing/tubing pressure passed  
039-03754 8/3/2007 Casing/tubing pressure passed  
039-03754 3/20/1998 Casing/tubing pressure passed  
039-03759 6/25/2010 Annulus pressure passed  
039-03759 6/4/2009 Annulus pressure failed  
039-03911 6/19/2008 Casing/tubing pressure failed  
039-03911 7/25/2002 Annulus pressure passed  
039-03911 8/7/1997 Casing/tubing pressure passed  
039-03911 4/20/1992 Casing/tubing pressure passed  
039-03912 6/19/2008 Casing/tubing pressure failed  
039-03912 11/15/2001 Casing/tubing pressure failed  
039-03912 11/3/2001 Annulus method passed  
039-03912 4/4/2001 Annulus method passed  
039-03912 4/3/1996 Casing/tubing pressure passed  
039-04202 4/24/2014 Annulus pressure passed  
039-04202 4/28/2009 Annulus pressure passed  
039-04202 3/21/1996 Casing/tubing pressure passed  
039-04844 5/3/2013 Annulus method passed  
039-04844 6/17/2008 Annulus method passed  
039-04844 10/26/2001 Casing/tubing pressure passed  
039-04844 10/10/2001 Annulus pressure failed  
039-04844 10/31/1996 Casing/tubing pressure passed  
039-04844 1/20/1992 Casing/tubing pressure passed  
039-04892 5/3/2013 Annulus method passed  
039-04892 6/17/2008 Annulus pressure passed  
039-04892 3/31/1998 Casing/tubing pressure passed  
039-04892 6/23/1993 Casing/tubing pressure passed  
041-00640 10/10/2002 Casing/tubing pressure passed  
041-00640 5/14/1997 Casing/tubing pressure passed  
041-00640 4/7/1992 Casing/tubing pressure passed  
041-02048 2/10/1993 Casing/tubing pressure passed  
041-03175 5/31/2013 Casing/tubing pressure passed  
041-03175 3/1/2006 Casing/tubing pressure passed pressured tubing to 1960 psi for 20 minutes with 40 psi bleeding off- standing valve
041-03175 1/22/1997 Casing/tubing pressure passed  
041-03175 11/29/1995 Casing/tubing pressure passed  
047-00062 8/6/2007 Annulus method passed  
047-00062 4/11/2007 Casing/tubing pressure failed Hole developed in tubing. Rigged up and found hole.Replaced joint of pipe and rerun and reset packer. Conduct MIT 
047-00062 2/8/2001 Casing/tubing pressure passed  
047-00062 5/12/1997 Casing/tubing pressure passed  
047-00062 11/18/1993 Casing/tubing pressure passed  
047-00062 11/17/1993 Annulus pressure failed  
047-00568 12/7/1993 Casing/tubing pressure passed  
047-00568 11/7/1992 Casing/tubing pressure passed  
047-01511 8/2/2010 Casing/tubing pressure passed  
047-01511 12/29/2008 Casing/tubing pressure passed  
047-01511 6/12/2008 Casing/tubing pressure failed  
047-01511 8/13/2002 Casing/tubing pressure passed  
055-00319 10/29/2015 Casing/tubing pressure passed Established MIT Procedure see UIC Permit 2D0550319 Attachment 3 for specific procedure details.
055-00319 1/1/2010 Annulus method passed  
061-00306 10/6/2006 Annulus pressure passed  
061-00306 9/15/1997 Casing/tubing pressure passed  
061-00306 9/20/1995 Casing/tubing pressure passed  
061-00306 7/22/1995 Annulus pressure failed  
061-00306 1/23/1992 Casing/tubing pressure passed  
061-00317 7/26/2010 Casing/tubing pressure passed  
061-00317 10/10/2008 Casing/tubing pressure passed  
061-00317 12/4/2006 Casing/tubing pressure failed  
073-02523 12/29/2011 Annulus pressure passed  
073-02523 3/3/2011 Annulus pressure passed  
073-02540 4/17/2015 Annulus method passed Pressure test was conducted and witnessed by inspector Joe Taylor and Mike Goff. intital pressure: 3678 psi and dropped to 3668psi after 20 minutes, >1% bleed
073-02540 5/1/2012 Annulus pressure passed  
079-01452 1/28/2014 Annulus method passed  
081-00281 1/17/2014 Annulus pressure passed  
081-00281 7/22/2009 Other passed  
081-00281 4/15/1996 Annulus pressure passed  
085-05076 1/26/2009 Annulus pressure passed  
085-05076 1/16/2001 Casing/tubing pressure passed  
085-05151 11/7/2014 Annulus pressure passed Submitted CBL log shows cement 100' above injection at ~2380', injection interval 2925'-2929', However VDL log shows potential poor bond above and below injection interval - microannulus(?)
085-05151 11/22/2010 Other passed Pipeline tightness test
085-05151 6/9/2009 Annulus pressure passed  
085-07569 2/15/1997 Annulus pressure passed  
085-07652 5/23/2008 Annulus method passed  
085-07652 5/10/2002 Annulus method passed  
085-07652 3/20/1996 Casing/tubing pressure passed  
085-08350 4/7/2010 Annulus pressure passed  
085-08350 5/10/2002 Annulus method passed  
085-08350 1/30/1996 Other passed  
085-09669 3/15/2010 Annulus pressure passed  
085-09721 4/12/2012 Annulus pressure passed  
085-09909 3/20/2013 Annulus pressure passed WR-40 Accumulated Volume Adjusted 12-2015
085-10142 2/25/2015 Annulus method passed 1900 psi was held with minimal bleed off 
087-00257 9/1/1998 Casing/tubing pressure passed  
087-00257 4/15/1992 Casing/tubing pressure passed  
087-00599 5/22/1996 Casing/tubing pressure passed  
087-00658 8/26/1997 Casing/tubing pressure passed  
087-00658 1/15/1992 Casing/tubing pressure passed  
087-00701 7/27/1998 Casing/tubing pressure passed  
087-00701 1/12/1993 Casing/tubing pressure passed  
087-00985 10/9/2013 Annulus method passed  
087-00985 9/2/2008 Annulus pressure passed  
087-00985 1/31/1994 Casing/tubing pressure passed  
087-01056 4/9/2014 Casing/tubing pressure passed  
087-01056 5/7/2009 Casing/tubing pressure passed  
087-01056 12/13/2002 Casing/tubing pressure passed  
087-01056 9/15/1997 Casing/tubing pressure passed  
087-01056 1/6/1992 Casing/tubing pressure passed  
087-01106 5/16/2012 Casing/tubing pressure passed  
087-01106 8/31/2006 Casing/tubing pressure failed  
087-01106 8/30/2006 Casing/tubing pressure passed  
087-01106 12/5/2000 Casing/tubing pressure passed  
087-01106 8/15/1995 Casing/tubing pressure passed  
087-01212 6/18/2013 Other passed  
087-01212 5/21/2008 Other passed  
087-01212 4/27/1995 Other passed  
087-01508 2/9/2009 Casing/tubing pressure passed  
087-01508 8/26/1997 Casing/tubing pressure passed  
087-01508 8/13/1992 Casing/tubing pressure passed  
087-01537 8/26/1997 Casing/tubing pressure passed  
087-01537 1/15/1992 Casing/tubing pressure passed  
087-01572 12/14/1995 Annulus pressure passed  
087-01578 4/21/1998 Other passed  
087-01578 2/3/1993 Annulus pressure passed  
087-01591 2/10/2009 Casing/tubing pressure passed  
087-01591 8/26/1997 Casing/tubing pressure passed  
087-01591 1/15/1992 Casing/tubing pressure passed  
087-01618 8/19/2014 Casing/tubing pressure passed MIT witnessed by inspector Ed Gainer 
087-01618 2/10/2009 Casing/tubing pressure passed  
087-01618 1/23/1997 Casing/tubing pressure passed  
087-01623 3/19/2014 Annulus pressure passed  
087-01623 10/3/2008 Casing/tubing pressure passed  
087-01623 9/19/1997 Casing/tubing pressure passed  
087-01623 7/23/1992 Casing/tubing pressure passed  
087-01637 12/10/2009 Other passed  
087-01637 4/21/1998 Other passed  
087-01637 2/3/1993 Annulus pressure passed  
087-01698 4/8/2009 Casing/tubing pressure failed  
087-01698 9/13/2001 Casing/tubing pressure passed  
087-01723 5/22/2013 Annulus method passed  
087-01723 6/2/2008 Annulus method passed  
087-01723 8/19/1997 Casing/tubing pressure passed  
087-01723 8/13/1992 Casing/tubing pressure passed  
087-01898 10/11/2010 Other passed  
087-01898 6/24/1998 Casing/tubing pressure passed  
087-01898 4/4/1995 Casing/tubing pressure passed  
087-01926 7/21/1994 Other passed  
087-01977 8/13/2015 Annulus method passed  
087-01977 7/15/2015 Annulus method passed Tubing re-ran with new packer. Joe Taylor witnessed MIT and granted verbal approval to commence. Gene Smith witenssed test and gave approval to operate
087-01977 6/15/2015 Annulus pressure passed 6/15/2015 casing lost pressure, issue was diagnosed "as minor leak on the surface gauge line"
087-01977 8/10/2010 Casing/tubing pressure passed  
087-01977 9/14/2007 Casing/tubing pressure passed  
087-01977 5/4/2006 Casing/tubing pressure passed  
087-01977 12/19/2001 Casing/tubing pressure passed  
087-01977 4/10/2001 Casing/tubing pressure passed  
087-01977 3/20/2001 Casing/tubing pressure failed  
087-01977 5/15/1997 Casing/tubing pressure passed  
087-01977 3/18/1992 Casing/tubing pressure passed  
087-02003 10/17/2013 Annulus pressure passed  
087-02003 8/20/2009 Other passed  
087-02003 4/19/2001 Annulus method passed  
087-02003 4/17/2001 Annulus pressure failed Developed leak on tubing annulus. Replaced tubing and set new packer. Loaded with fresh water and plan to pressure test.
087-02003 1/16/1997 Casing/tubing pressure passed  
087-02075 7/27/1999 Other passed  
087-02076 10/19/1992 Casing/tubing pressure passed  
087-02088 8/4/1999 Annulus pressure passed  
087-02092 8/4/1999 Annulus method passed  
087-02099 8/4/1999 Annulus method passed  
087-02101 5/18/1999 Other passed  
087-02102 8/4/1999 Other passed  
087-02103 5/18/1999 Other passed  
087-02103 7/23/1992 Casing/tubing pressure passed  
087-02103 7/16/1992 Casing/tubing pressure failed  
087-02106 5/18/1999 Other passed  
087-02107 5/19/1999 Other passed  
087-02402 5/19/1999 Other passed  
087-02404 5/19/1999 Other passed  
087-02405 11/18/1999 Annulus method passed  
087-02406 9/3/1998 Other passed  
087-02407 5/28/1998 Casing/tubing pressure passed  
087-02408 11/18/1999 Annulus method passed  
087-02409 5/20/1998 Casing/tubing pressure passed  
087-02410 8/4/1999 Other passed  
087-02411 3/29/1998 Casing/tubing pressure passed  
087-02446 4/20/1995 Annulus pressure failed  
087-02446 2/16/1995 Annulus pressure failed  
087-02490 5/22/1996 Casing/tubing pressure passed  
087-02554 9/3/1998 Other passed  
087-02554 4/24/1992 Annulus pressure passed  
087-02638 11/17/1999 Annulus method passed  
087-02638 12/6/1993 Casing/tubing pressure passed  
087-02778 11/4/1999 Annulus method passed  
087-02844 11/18/1999 Annulus method passed  
087-02941 7/24/1998 Casing/tubing pressure passed  
087-02941 4/10/1992 Casing/tubing pressure passed  
087-02942 5/19/1999 Other passed  
087-02969 4/9/1994 Annulus pressure passed  
087-02975 10/3/2014 Casing/tubing pressure passed  
087-02975 10/15/2009 Casing/tubing pressure passed  
087-02976 11/2/1994 Casing/tubing pressure passed  
087-03096 9/23/1992 Casing/tubing pressure passed  
087-03129 7/7/1998 Casing/tubing pressure passed  
087-03146 10/28/1999 Annulus method passed  
087-03146 8/26/1993 Casing/tubing pressure passed  
087-03146 12/25/1992 Annulus pressure failed  
087-03146 12/16/1992 Casing/tubing pressure passed  
087-03324 5/19/1999 Other passed  
087-03334 6/10/2008 Casing/tubing pressure passed  
087-03334 7/8/1996 Casing/tubing pressure passed  
087-03348 6/30/2014 Casing/tubing pressure passed  
087-03348 7/17/2007 Casing/tubing pressure passed  
087-03348 7/24/1996 Casing/tubing pressure passed  
087-03349 11/2/2007 Casing/tubing pressure passed  
087-03349 7/25/1996 Casing/tubing pressure passed  
087-03398 8/26/1998 Casing/tubing pressure passed  
087-03398 4/6/1992 Casing/tubing pressure passed  
087-03399 5/21/1999 Other passed  
087-03400 5/19/1999 Other passed  
087-03401 5/19/1999 Other passed  
087-03407 5/19/1999 Other passed  
087-03409 7/10/1996 Casing/tubing pressure passed  
087-03410 5/21/1999 Other passed  
087-03411 5/20/1999 Other passed  
087-03412 5/20/1999 Other passed  
087-03413 5/20/1999 Other passed  
087-03414 5/20/1999 Other passed  
087-03414 6/28/1994 Annulus pressure failed  
087-03416 5/20/1999 Other passed  
087-03432 10/9/2013 Annulus pressure passed  
087-03432 9/9/2013 Annulus pressure failed  
087-03432 7/3/2008 Casing/tubing pressure passed  
087-03432 10/31/2001 Annulus method passed  
087-03432 9/18/2001 Annulus pressure failed  
087-03432 8/28/1996 Casing/tubing pressure passed  
087-03436 6/19/2014 Casing/tubing pressure passed  
087-03436 1/25/2007 Casing/tubing pressure passed  
087-03436 7/29/1996 Casing/tubing pressure passed  
087-03438 8/25/1995 Casing/tubing pressure passed  
087-03447 9/30/2008 Casing/tubing pressure passed  
087-03447 8/14/1996 Casing/tubing pressure passed  
087-03457 10/16/2007 Annulus pressure passed  
087-03457 7/23/1996 Casing/tubing pressure passed  
087-03589 12/10/1993 Casing/tubing pressure passed  
087-03589 10/13/1993 Annulus pressure failed  
087-03589 10/11/1993 Annulus pressure failed  
087-03591 7/19/1994 Casing/tubing pressure passed  
087-03591 6/7/1994 Annulus pressure failed  
087-03592 8/19/2008 Casing/tubing pressure passed  
087-03593 11/14/2008 Casing/tubing pressure passed  
087-03595 3/15/2007 Casing/tubing pressure passed  
087-03595 4/1/1998 Annulus pressure failed  
087-03604 10/25/1995 Other passed  
087-03605 12/15/1995 Other passed  
087-03608 12/1/1995 Other passed  
087-03609 11/3/1999 Annulus method passed  
087-03630 3/29/2007 Casing/tubing pressure passed Ran 2 3/8" tubing with Baker tension packer set at 2363' and pressured to 1510 psi for 30 minutes.
087-03630 8/14/1998 Annulus pressure failed  
087-03631 6/19/2014 Casing/tubing pressure passed  
087-03631 6/18/2008 Casing/tubing pressure passed  
087-03632 7/9/2014 Casing/tubing pressure passed  
087-03632 7/7/2008 Casing/tubing pressure passed  
087-03634 6/30/2014 Casing/tubing pressure passed  
087-03634 6/30/2007 Casing/tubing pressure passed  
087-03634 11/2/1994 Casing/tubing pressure passed  
087-03634 6/7/1994 Annulus pressure failed  
087-03634 5/6/1994 Casing/tubing pressure passed  
087-03634 3/10/1994 Annulus pressure failed  
087-03634 11/29/1993 Casing/tubing pressure passed  
087-03634 10/25/1993 Annulus pressure failed  
087-03634 10/7/1993 Annulus pressure failed  
087-03634 5/12/1993 Casing/tubing pressure passed  
087-03635 1/11/2007 Casing/tubing pressure passed  
087-03635 6/19/1992 Annulus pressure passed  
087-03651 7/19/2014 Casing/tubing pressure passed  
087-03651 12/11/2006 Casing/tubing pressure passed  
087-03659 11/17/1999 Annulus method passed  
087-03660 11/17/1999 Annulus method passed  
087-03661 9/3/1998 Other passed  
087-03662 9/3/1998 Other passed  
087-03664 11/3/1999 Annulus method passed  
087-03674 9/4/1998 Other passed  
087-03674 8/25/1994 Annulus pressure failed  
087-03675 5/14/1998 Other passed  
087-03675 5/19/1993 Casing/tubing pressure passed  
087-03675 4/21/1993 Annulus pressure failed  
087-03764 7/3/2014 Casing/tubing pressure passed  
087-03764 10/26/2007 Casing/tubing pressure passed  
087-03766 11/3/1999 Annulus method passed  
087-03767 11/4/1999 Annulus method passed  
087-03768 11/4/1999 Annulus method passed  
087-03769 11/4/1999 Annulus method passed  
087-03771 6/24/1998 Casing/tubing pressure passed  
087-03771 4/23/1992 Annulus pressure passed  
087-03772 11/4/1999 Annulus method passed  
087-03773 11/4/1999 Annulus method passed  
087-03774 3/27/2012 Annulus pressure passed  
087-03774 10/2/1995 Casing/tubing pressure passed  
087-03775 11/17/1999 Annulus method passed  
087-03776 11/4/1999 Annulus method passed  
087-03778 1/10/2000 Annulus method passed  
087-03778 6/26/1992 Casing/tubing pressure passed  
087-03778 1/22/1992 Annulus pressure failed  
087-03779 7/15/1998 Casing/tubing pressure passed  
087-03779 4/23/1992 Annulus pressure passed  
087-03780 9/4/1998 Other passed  
087-03781 10/3/1995 Casing/tubing pressure passed  
087-03875 11/17/1999 Annulus method passed  
087-03875 11/8/1994 Casing/tubing pressure passed  
087-03876 3/15/1995 Casing/tubing pressure passed  
087-03877 11/3/1999 Annulus method passed  
087-03878 1/10/2000 Annulus method passed  
087-03878 12/6/1994 Casing/tubing pressure passed  
087-03879 9/4/1998 Other passed  
087-03880 4/5/2012 Annulus pressure passed  
087-03880 3/16/1995 Casing/tubing pressure passed  
087-03884 3/14/1995 Casing/tubing pressure passed  
087-03885 10/28/1999 Annulus method passed  
087-03885 12/28/1994 Casing/tubing pressure passed  
087-03887 7/7/2014 Casing/tubing pressure passed  
087-03887 5/21/2007 Casing/tubing pressure passed  
087-03887 4/18/1994 Casing/tubing pressure passed  
087-03887 6/19/1992 Annulus pressure passed  
087-03888 7/15/2014 Casing/tubing pressure passed  
087-03888 5/30/2007 Casing/tubing pressure passed  
087-03888 8/2/1994 Casing/tubing pressure passed  
087-03889 8/1/2007 Casing/tubing pressure passed  
087-03889 7/28/1994 Casing/tubing pressure passed  
087-03890 5/8/2007 Casing/tubing pressure passed  
087-03890 1/8/1998 Annulus pressure failed  
087-03890 7/29/1994 Casing/tubing pressure passed  
087-03910 6/19/2014 Casing/tubing pressure passed  
087-03910 6/12/2008 Casing/tubing pressure passed  
087-03910 7/26/1994 Casing/tubing pressure passed  
087-03974 1/6/2000 Casing/tubing pressure passed  
087-03974 3/25/1994 Other passed  
087-03976 1/11/2000 Casing/tubing pressure passed  
087-03976 3/25/1994 Other passed  
087-03977 3/17/1995 Casing/tubing pressure passed  
087-03978 7/7/2014 Casing/tubing pressure passed  
087-03978 7/12/2007 Casing/tubing pressure passed  
087-03978 7/11/1996 Casing/tubing pressure passed  
087-04013 11/17/1999 Annulus method passed  
087-04013 3/25/1994 Other passed  
087-04016 8/30/1996 Casing/tubing pressure passed  
087-04078 1/6/2000 Casing/tubing pressure passed  
087-04078 10/17/1993 Annulus pressure passed  
087-04079 9/6/2005 Annulus method passed  
087-04079 1/6/2000 Annulus method passed  
087-04079 10/4/1993 Annulus pressure passed  
087-04080 9/14/2005 Annulus method passed  
087-04080 1/6/2000 Annulus pressure passed  
087-04080 10/6/1993 Annulus pressure passed  
087-04081 10/11/1993 Annulus pressure passed  
087-04087 1/7/2000 Annulus method passed  
087-04087 10/20/1993 Annulus pressure passed  
087-04089 11/8/1993 Other passed  
087-04164 7/31/1998 Casing/tubing pressure passed  
087-04165 7/29/1998 Casing/tubing pressure passed  
087-04166 12/21/1999 Annulus method passed  
087-04171 9/16/2005 Annulus method passed  
087-04171 1/6/2000 Annulus method passed  
087-04172 7/28/1998 Casing/tubing pressure passed  
087-04481 10/15/2012 Other passed  
087-04481 10/10/2007 Casing/tubing pressure passed  
087-04724 7/13/2015 Annulus method passed CBL/VDL = good external internal, good overall bond from Big Injun injection zone 2167' to TOC ~850'. Internal integrity tested 4 1/2" x 2 3/8" annulus loss from 1620 psi to 1560 over 20 min ~3.7%, witnessed & approved by Joe Taylor
087-04745 3/17/2015 Annulus method passed CBL/VDL log shows good bond over 4.5" casing (TOC=~40'), angle drilled well, perforations:2234-2242 (MD) packer:2115 (MD)
087-04747 3/19/2015 Annulus method passed CBL/VDL good over entire 4.5'" casing (TOC ~45'), packer:2404' (MD) perforations: :2524-2532' (MD)
087-04749 5/29/2015 Annulus method passed CBL/VDL shows good over entire 4.5" casing (TOC ~40')), angle drilled well, packer:2177.5' (MD), perforation:2284-2292' (MD)
087-04751 6/8/2015 Annulus method passed CBL/VDL log shows overall good bond of 4.5" casing from injection formation to TOC (~750"), packer=2340, perforations 2466-2476' (MD)
087-04753 5/21/2015 Annulus method passed 4.5" CBL/VDL shows good cement to casing and fomration above injection formation (Big Injun) hole is angle drilled
087-04754 5/21/2015 Annulus method passed 4.5" CBL/VDL shows good overall bond above injection formation (Big Injun), hole is angle drilled
087-04755 5/21/2015 Annulus method passed 4.5" CBL/VDL shows good overall bond above the injection formation (Big Injun) hole is angle drilled
087-04756 10/14/2015 Annulus method passed Pressure test witnessed and signed/approved by inspector Joe Taylor, pressured well to 1650 after 30 minutes pressure drop to 1625 (~1.5%), external integrity verified using CBL/VDL good cement throughtout 4.5 casing frrom to TOC at 119'
087-04757 9/21/2015 Annulus pressure passed Pressure test was witnessed and signed by inspector Joe Taylor, pressured well to 1600 psi and dropped just below 1600 psi after 30 minutes (submitted chart difficult to determine actually pressure loss), external was verified using cementing records, how
087-04758 7/28/2015 Annulus pressure passed Pressure tested tubing/casing annulus to 1600 psi for 35 min, witnessed and signed approval by Inspector Joe Taylor for internal integrity, external integrity verified by CBL/VDL good bond overall to TOC 43'
087-04759 7/30/2015 Annulus method passed Pressure test witnessed and signed by inspector Joe Taylor, pressured well to1650psi with no recognizable pressure loss according to chart. External integrity verified by CBL/VDL with overall good bond (>80%) on 4.5 casing over 2450 to surface (CTS)
087-04760 8/24/2015 Annulus method passed Pressure test was witnessed and signed by inspector Joe Taylor, pressured well to 1620 psi for 30 minutes well lost ~20 psi by the end of test, (~1.2% loss). External integrity used cement casing information however a request was sent to operator to submi
087-04761 8/24/2015 Annulus method passed Pressure test was wtinessed and signed by inspector Joe Taylor, pressured well to 1620psi for 20 minutes appears have 20 psi by the end of test (~1.1% loss), External integtrity verified using cement records however the applicant was requested to submit t
087-04762 9/21/2015 Annulus method passed Pressure test witnessed and signed by inspector Joe Taylor, pressure chart shows 1625 psi and drop to 1600 after 25 mintues, ~1.5% loss. External integrity verfied using CBL/VDL, good bond (>80%) in 4.5 casing from 380" (TOC) to 2450', perforattions 2352
087-04763 7/13/2015 Annulus pressure passed Pressure tested tubing/casing annulus at 1620 psi for 20 minutes, witnessed and signed by inspector Joe Taylor, pressure chart diffifcult to determine actualpressures, relying in inspector approval for internal integrity, external integrity was verified
087-04764 7/13/2015 Annulus pressure passed Pressure test witnessed and signed by inspector Joe Taylor, pressured well to 1620 psi for 20 minutes chart appears to show no loss during test (0%), External integrity verified using CBL/VDL bond appears to be very good on 4.5 casing from TD to surface (
087-04765 7/21/2015 Annulus method passed Pressure test was witnessed and signed by inspector Joe Taylor. Pressured well 1600 psi for 35 minutes pressure chart shows zero pressure loss (0%), External integrity verified by CBL/VDL of 4.5 casing, good bopnd from 2200' to 68' (TOC)
087-04766 8/11/2015 Annulus pressure passed Pressure test tubing/casing annulus to 1620 for 25 min, witnessed and signed for approcal by inspector Joe Taylor for internal integrity, external integrity was verified using CBL/VDL shows overall good bond to TOC surface 
087-04767 7/21/2015 Annulus pressure passed Pressure tested tubing/casing annulus to 1600 psi for 35 min, witnessed and signed approval by inspector Joe Taylor for internal integrity. external integrity was verified using CBL/VDL with good bond overall to TOC 53'
087-04768 8/14/2015 Annulus method passed Pressure test witnessed and signed/approved by inspector Joe Taylor, pressured well to 1610 psi with drop 1575 psi after 30 minutes (~2.2 % loss), external integrity verified using CBL/VDL, well shows good cement bond throughout 4.5 casing, TOC ~18'
087-04780 10/16/2015 Annulus method passed Pressure test witnessed and signed/approved by inspector Joe Taylor, pressured well 1625 with ~0% loss after 35 minutes, External integtity verified by CBL/VDL good cement good throughout 4.5 casing, appears to be CTS
087-04781 8/11/2015 Annulus method passed Pressure test was witnessed and signed by inspector Joe Taylor, pressured well to 1600 for 25 minutes zero psi (0%) loss after test was completed. External integrity was verified using CBL/VDL, good bond throughout 4.5 casing from 110' (TOC) to 2470
087-04782 8/12/2015 Annulus method passed Test was witnessed and signed by inspector Joe Taylor, pressured well to 1600 psi for 30 minutes pressure dropped to 1525 psi (~4.6% loss), external integity verified using CBL/VDL 4.5 casing had good overall cement from 48' (TOC) - 2470'
093-00081 2/10/2012 Annulus pressure passed  
093-00081 5/18/2004 Annulus pressure passed Jamie and Craig witnessed
093-00103 2/2/2012 Annulus pressure passed  
093-00103 4/2/2008 Casing/tubing pressure passed  
097-03422 4/20/2015 Annulus method passed Tested 2x4 1/2 annulus pressured 1 hour and bled from 1089 to 1074.
097-03422 7/5/2012 Annulus pressure passed  
097-03422 5/25/2012 Annulus pressure failed Tested at 700psi for only 15 minutes. Should be between 810-1080psi for 20 minutes.
097-03422 11/15/2010 Annulus pressure passed  
097-03737 9/1/2011 Casing/tubing pressure passed  
103-00906 4/11/2014 Other passed  
103-00906 4/17/2008 Casing/tubing pressure passed  
103-00906 5/17/2002 Monitor record review passed  
103-00906 10/30/1996 Casing/tubing pressure passed  
103-00947 5/24/2013 Other passed  
103-00947 3/10/2008 Casing/tubing pressure passed  
103-00947 5/4/2002 Monitor record review passed  
103-00947 1/31/1996 Casing/tubing pressure passed  
103-00964 3/21/2002 Casing/tubing pressure failed  
103-00984 3/21/2002 Casing/tubing pressure passed  
103-00984 4/17/1998 Other passed  
103-00984 6/7/1994 Annulus pressure failed  
103-00984 2/17/1994 Casing/tubing pressure passed  
103-00985 10/1/2002 Monitor record review passed  
103-00985 4/25/1995 Casing/tubing pressure passed  
103-00985 8/4/1994 Annulus pressure failed  
103-00985 5/3/1994 Casing/tubing pressure passed  
103-00985 3/18/1994 Annulus pressure failed  
103-00985 10/28/1993 Casing/tubing pressure passed  
103-00986 10/1/2002 Monitor record review passed  
103-00986 3/30/1994 Annulus pressure failed  
103-00986 2/23/1994 Casing/tubing pressure passed  
103-01171 5/19/1997 Casing/tubing pressure passed  
103-01288 9/28/2000 Casing/tubing pressure failed  
103-01315 8/24/2010 Other passed  
103-01315 8/16/2006 Casing/tubing pressure passed  
103-01315 3/21/2000 Casing/tubing pressure passed  
103-01315 1/3/2000 Casing/tubing pressure passed  
103-01315 8/14/1996 Casing/tubing pressure passed  
103-01315 3/7/1995 Casing/tubing pressure passed  
103-01415 12/2/2009 Casing/tubing pressure passed  
103-01415 1/8/1997 Casing/tubing pressure passed  
103-01514 3/25/2014 Casing/tubing pressure passed  
103-01514 4/17/2003 Casing/tubing pressure passed  
103-01514 4/17/1998 Other passed  
103-01514 10/31/1992 Casing/tubing pressure passed  
103-01515 6/6/1997 Casing/tubing pressure passed  
103-01515 11/7/1992 Casing/tubing pressure passed  
103-01516 3/25/2014 Casing/tubing pressure passed  
103-01516 10/7/2003 Casing/tubing pressure passed  
103-01516 4/17/1998 Other passed  
103-01516 11/14/1992 Casing/tubing pressure passed  
103-01530 10/2/2002 Monitor record review passed  
103-01530 6/11/1994 Annulus pressure failed  
103-01530 5/12/1994 Casing/tubing pressure passed  
103-01540 5/1/2014 Casing/tubing pressure passed  
103-01540 6/7/2010 Casing/tubing pressure passed  
103-01540 1/27/2009 Casing/tubing pressure failed  
103-01540 7/13/2004 Casing/tubing pressure passed  
103-01540 8/24/1998 Other passed  
103-01540 8/30/1993 Casing/tubing pressure passed  
103-01541 5/9/2003 Casing/tubing pressure passed  
103-01541 10/20/1998 Other passed  
103-01541 10/28/1993 Casing/tubing pressure passed  
103-01542 7/17/2015 Casing/tubing pressure passed bridge plug at 2825', pressured to 1775 psi tested 20 min
103-01542 7/15/2010 Other passed  
103-01542 9/24/2003 Casing/tubing pressure passed  
103-01542 9/17/1998 Other passed  
103-01542 9/14/1993 Casing/tubing pressure passed  
103-01543 7/28/2015 Casing/tubing pressure passed retrievable bridge plug set at 3060' pressure at 1700 psi for 20 min, < 5% loss, well was drilled in 1993 meaning it should have tubing and packer arrangement = NOT "grandfathered"
103-01543 7/22/2010 Other passed  
103-01543 10/21/2003 Casing/tubing pressure passed  
103-01543 8/8/1998 Other passed  
103-01543 8/12/1993 Casing/tubing pressure passed  
103-01544 7/21/2015 Casing/tubing pressure passed Bridge plug set at 2795'n, pressure tested at 1800 psi for ~24 min
103-01544 7/15/2010 Other passed  
103-01544 9/29/2003 Casing/tubing pressure passed  
103-01544 10/6/1998 Other passed  
103-01544 10/6/1993 Casing/tubing pressure passed  
103-01545 7/13/2015 Casing/tubing pressure passed retrievable bridge plug at 2700' pressure at 1700 psi, < 5% loss, *well was drilled in 1993 meaning it should have tubing and packer arrangement = NOT "grandfathered"
103-01545 7/6/2010 Other passed  
103-01545 6/3/2003 Casing/tubing pressure passed  
103-01545 10/12/1998 Other passed  
103-01545 10/13/1993 Casing/tubing pressure passed  
103-01546 7/15/2010 Other passed  
103-01546 9/26/2003 Annulus pressure passed  
103-01546 9/14/1998 Other passed  
103-01546 9/14/1993 Casing/tubing pressure passed  
103-01547 7/23/2015 Casing/tubing pressure passed Bridge plug at 2955', pressure tested 1850 psi for 25 minutes, submitted shart shows 0 loss
103-01547 7/15/2010 Other passed  
103-01547 9/29/2004 Casing/tubing pressure passed  
103-01547 9/14/1998 Other passed  
103-01565 7/9/2009 Other passed  
103-01621 6/3/2002 Monitor record review passed  
103-01625 7/24/2015 Casing/tubing pressure passed retrievable bridge plug at 2944' pressure at 1700 psi for 20 minutes, < 5% loss, well was drilled 1994 which means it should have a tubing and ;packer arrangement =- NOT "grandfathered"
103-01625 7/22/2010 Other passed  
103-01625 2/25/2005 Casing/tubing pressure passed  
103-01625 11/11/1999 Casing/tubing pressure passed  
103-01625 8/13/1994 Casing/tubing pressure passed  
103-01626 8/21/2015 Casing/tubing pressure passed retrievable bridge plug at 2860' a=pressure at 1700 psi for 20 minutes, < %5 loss, well was drilled 1994 meaning it should have tubing and packer arrangement, = NOT "grandfathered"
103-01626 8/4/2010 Other passed  
103-01626 2/22/2005 Casing/tubing pressure failed  
103-01626 11/10/1999 Casing/tubing pressure failed  
103-01626 8/20/1994 Casing/tubing pressure passed  
103-01627 2/8/2013 Other passed  
103-01627 11/29/2007 Casing/tubing pressure passed  
103-01627 6/5/2002 Monitor record review passed  
103-01627 8/1/1996 Annulus pressure passed  
103-01627 8/24/1994 Casing/tubing pressure passed  
103-01628 4/23/2013 Other passed  
103-01628 8/4/2010 Other passed  
103-01628 2/22/2005 Casing/tubing pressure passed  
103-01628 5/4/2002 Monitor record review passed  
103-01628 1/1/1999 Casing/tubing pressure passed  
103-01628 9/15/1994 Casing/tubing pressure passed  
103-01631 2/5/2013 Other passed  
103-01631 12/4/2007 Casing/tubing pressure passed  
103-01631 10/1/2002 Monitor record review passed  
103-01631 9/15/1994 Casing/tubing pressure passed  
103-01632 8/4/2010 Other passed  
103-01632 2/24/2005 Casing/tubing pressure passed  
103-01632 6/15/2000 Casing/tubing pressure passed  
103-01632 5/25/1995 Casing/tubing pressure passed  
103-01633 8/4/2010 Other passed  
103-01633 2/24/2005 Casing/tubing pressure passed  
103-01633 8/20/1999 Other passed  
103-01633 10/10/1994 Casing/tubing pressure passed  
103-01634 4/24/2014 Other passed  
103-01634 7/10/2009 Other passed  
103-01634 7/19/2004 Casing/tubing pressure passed  
103-01634 8/20/1999 Other passed  
103-01634 9/15/1994 Casing/tubing pressure passed  
103-01635 7/22/2010 Other passed  
103-01635 2/25/2005 Casing/tubing pressure passed  
103-01635 8/20/1999 Other passed  
103-01635 8/21/1994 Casing/tubing pressure passed  
103-01641 3/25/2014 Casing/tubing pressure passed  
103-01641 1/12/2009 Annulus method passed  
103-01641 10/3/2002 Annulus pressure passed  
103-01641 8/1/1996 Annulus pressure passed  
103-01641 11/13/1994 Casing/tubing pressure passed  
103-01642 5/29/2014 Casing/tubing pressure passed  
103-01642 7/2/2009 Other passed  
103-01642 8/26/2004 Casing/tubing pressure passed  
103-01642 11/9/1999 Casing/tubing pressure passed  
103-01642 11/17/1994 Casing/tubing pressure passed  
103-01643 8/16/2010 Other passed  
103-01643 2/3/2005 Casing/tubing pressure passed  
103-01643 8/20/1999 Other passed  
103-01643 11/18/1994 Casing/tubing pressure passed  
103-01644 8/30/2013 Other passed  
103-01644 11/30/2007 Casing/tubing pressure passed  
103-01644 6/5/2002 Monitor record review passed  
103-01644 7/26/1996 Annulus pressure passed  
103-01644 10/12/1994 Casing/tubing pressure passed  
103-01645 8/16/2010 Other passed  
103-01645 2/11/2005 Casing/tubing pressure passed  
103-01645 6/15/2000 Casing/tubing pressure passed  
103-01645 12/12/1994 Casing/tubing pressure passed  
103-01657 1/4/2013 Other passed  
103-01657 12/20/2007 Casing/tubing pressure passed  
103-01657 10/1/2002 Monitor record review passed  
103-01657 7/19/1995 Casing/tubing pressure passed  
103-01658 7/22/2010 Other passed  
103-01658 2/7/2003 Annulus method passed  
103-01658 2/22/1996 Casing/tubing pressure passed  
103-01659 9/9/2013 Other passed  
103-01659 3/31/2008 Casing/tubing pressure passed  
103-01659 5/17/2002 Monitor record review passed  
103-01659 6/17/1996 Casing/tubing pressure passed  
103-01660 3/26/2014 Casing/tubing pressure passed  
103-01660 8/16/2006 Annulus method passed fluid levels 
103-01660 2/8/2001 Annulus method passed  
103-01660 9/8/1995 Casing/tubing pressure passed  
103-01671 12/18/2012 Other passed  
103-01671 5/21/2007 Casing/tubing pressure passed  
103-01671 4/23/2002 Monitor record review passed  
103-01671 8/7/1995 Casing/tubing pressure passed  
103-01672 4/23/2013 Other passed  
103-01672 5/30/2007 Casing/tubing pressure passed  
103-01672 4/20/2002 Monitor record review passed  
103-01672 8/23/1995 Casing/tubing pressure passed  
103-01673 12/20/2012 Other passed  
103-01673 5/29/2007 Casing/tubing pressure passed  
103-01673 7/20/2000 Monitor record review failed  
103-01673 7/28/1995 Casing/tubing pressure passed  
103-01675 5/21/2013 Other passed  
103-01675 1/10/2008 Casing/tubing pressure passed  
103-01675 10/1/2002 Monitor record review passed  
103-01675 7/31/1995 Casing/tubing pressure passed  
103-01676 12/10/2012 Other passed  
103-01676 4/18/2007 Casing/tubing pressure passed set bridge in 4 1/2 " above Gordon perfs and P test to 2150# for 23 minutes
103-01676 4/23/2002 Monitor record review passed  
103-01676 10/11/1995 Casing/tubing pressure passed  
103-01677 8/16/2010 Other passed  
103-01677 2/15/2005 Casing/tubing pressure passed  
103-01677 9/15/2000 Casing/tubing pressure passed  
103-01677 6/28/1995 Casing/tubing pressure passed  
103-01678 5/1/2013 Other passed  
103-01678 3/13/2008 Casing/tubing pressure passed  
103-01678 10/1/2002 Monitor record review passed  
103-01678 8/21/1995 Casing/tubing pressure passed  
103-01679 8/24/2010 Other passed  
103-01679 5/4/2002 Annulus method passed fluid levels 
103-01679 10/12/1995 Casing/tubing pressure passed  
103-01685 12/19/2012 Other passed  
103-01685 11/9/2007 Casing/tubing pressure passed  
103-01685 12/16/2002 Monitor record review passed  
103-01685 10/8/1996 Casing/tubing pressure passed  
103-01688 3/26/2014 Casing/tubing pressure passed  
103-01688 8/16/2006 Annulus method passed  
103-01688 2/8/2001 Annulus method passed  
103-01688 8/21/1995 Casing/tubing pressure passed  
103-01692 12/10/2012 Other passed  
103-01692 5/31/2007 Casing/tubing pressure passed  
103-01692 4/23/2002 Monitor record review passed  
103-01692 8/21/1995 Casing/tubing pressure passed  
103-01693 12/27/2012 Other passed  
103-01693 6/7/2007 Casing/tubing pressure passed  
103-01693 5/20/2002 Monitor record review passed  
103-01693 6/3/1996 Casing/tubing pressure passed  
103-01694 6/12/2013 Other passed  
103-01694 3/16/2008 Casing/tubing pressure passed  
103-01694 5/4/2002 Monitor record review passed  
103-01694 6/27/1996 Casing/tubing pressure passed  
103-01695 1/2/2013 Other passed  
103-01695 6/7/2007 Casing/tubing pressure passed  
103-01695 7/23/2002 Monitor record review passed  
103-01695 6/9/1996 Casing/tubing pressure passed  
103-01696 4/29/2013 Other passed  
103-01696 3/16/2008 Casing/tubing pressure passed  
103-01696 10/2/2002 Monitor record review passed  
103-01696 6/27/1996 Casing/tubing pressure passed  
103-01699 8/7/2013 Other passed  
103-01699 6/4/2007 Casing/tubing pressure passed  
103-01699 10/17/2002 Monitor record review passed  
103-01699 7/13/1996 Monitor record review passed  
103-01702 4/29/2013 Other passed  
103-01702 6/4/2007 Casing/tubing pressure passed  
103-01702 10/9/2002 Monitor record review passed  
103-01702 7/8/1996 Monitor record review passed  
103-01704 11/28/2012 Other passed  
103-01704 11/8/2007 Casing/tubing pressure passed  
103-01704 12/16/2002 Monitor record review passed  
103-01704 11/9/1996 Casing/tubing pressure passed  
103-01705 12/19/2012 Other passed  
103-01705 11/14/2007 Casing/tubing pressure passed  
103-01705 12/14/2002 Casing/tubing pressure passed  
103-01705 12/18/1996 Casing/tubing pressure passed  
103-01706 1/4/2013 Other passed  
103-01706 11/14/2007 Casing/tubing pressure passed  
103-01706 12/16/2002 Monitor record review passed  
103-01706 10/3/1996 Casing/tubing pressure passed  
103-01707 11/29/2012 Other passed  
103-01707 11/15/2007 Casing/tubing pressure passed  
103-01707 11/30/2002 Monitor record review passed  
103-01708 4/2/2013 Other passed  
103-01708 3/14/2008 Casing/tubing pressure passed  
103-01708 11/24/2002 Monitor record review passed  
103-01708 12/3/1996 Monitor record review passed  
103-01709 3/28/2013 Other passed  
103-01709 3/16/2008 Casing/tubing pressure passed  
103-01709 11/27/2002 Monitor record review passed  
103-01709 11/24/2002 Monitor record review passed  
103-01709 11/19/1996 Monitor record review passed  
103-01710 3/20/2008 Casing/tubing pressure passed  
103-01710 12/5/2002 Monitor record review passed  
103-01710 12/10/1996 Casing/tubing pressure passed  
103-01711 3/20/2013 Other passed  
103-01711 11/9/2007 Casing/tubing pressure passed  
103-01711 11/30/2002 Monitor record review passed  
103-01711 10/8/1996 Casing/tubing pressure passed  
103-01716 3/19/2013 Other passed  
103-01716 3/24/2008 Casing/tubing pressure passed  
103-01716 12/2/2002 Other passed fluid levels 
103-01716 10/22/1996 Casing/tubing pressure passed  
103-01717 3/22/2013 Other passed  
103-01717 3/25/2008 Casing/tubing pressure passed  
103-01717 12/2/2002 Monitor record review passed  
103-01717 10/16/1996 Monitor record review passed  
103-01718 11/7/2012 Other passed  
103-01718 10/25/2007 Casing/tubing pressure passed  
103-01718 11/20/2002 Monitor record review passed  
103-01718 12/28/1996 Casing/tubing pressure passed  
103-01719 11/2/2012 Other passed  
103-01719 10/23/2007 Casing/tubing pressure passed  
103-01719 11/20/2002 Monitor record review passed  
103-01719 1/3/1997 Casing/tubing pressure passed  
103-01720 11/6/2012 Other passed  
103-01720 10/23/2007 Annulus method passed  
103-01720 11/23/2002 Monitor record review passed  
103-01720 9/22/1997 Casing/tubing pressure passed  
103-01721 12/3/2012 Other passed  
103-01721 11/15/2007 Casing/tubing pressure passed  
103-01721 11/30/2002 Monitor record review passed  
103-01721 11/16/1996 Casing/tubing pressure passed  
103-01739 2/27/2014 Annulus method passed  
103-01742 10/11/2012 Other passed  
103-01742 10/29/2007 Casing/tubing pressure passed  
103-01742 11/27/2002 Monitor record review passed  
103-01742 8/18/1997 Casing/tubing pressure passed  
103-01743 10/9/2012 Other passed  
103-01743 10/26/2007 Casing/tubing pressure passed  
103-01743 11/26/2002 Monitor record review passed  
103-01743 8/24/1997 Casing/tubing pressure passed  
103-01747 9/17/2013 Annulus method passed  
103-01748 11/20/2002 Monitor record review passed  
103-01749 10/26/2012 Annulus pressure passed  
103-01749 10/25/2007 Casing/tubing pressure passed  
103-01749 11/23/2002 Monitor record review passed  
103-01749 8/28/1997 Casing/tubing pressure passed  
103-01777 1/17/2013 Other passed  
103-01777 1/10/2007 Casing/tubing pressure passed  
103-01783 5/6/2014 Other passed  
103-01913 4/18/2013 Other passed  
103-01950 7/14/2003 Casing/tubing pressure passed  
103-01970 7/15/2010 Other passed  
103-01970 10/23/2003 Casing/tubing pressure failed  
103-02028 3/12/2008 Casing/tubing pressure passed  
103-02105 12/11/2012 Other passed  
103-02105 10/1/2007 Casing/tubing pressure passed  
103-02126 12/8/2005 Casing/tubing pressure passed  
103-02203 1/14/2013 Other passed  
103-02203 1/10/2007 Casing/tubing pressure passed  
103-02205 1/16/2013 Other passed  
103-02205 2/20/2007 Casing/tubing pressure passed  
103-02211 3/29/2007 Casing/tubing pressure failed  
103-02217 10/10/2008 Casing/tubing pressure passed  
103-02220 12/12/2012 Other passed  
103-02220 3/21/2007 Casing/tubing pressure passed  
103-02221 12/4/2012 Other passed  
103-02221 3/27/2007 Casing/tubing pressure passed  
103-02222 12/4/2012 Other passed  
103-02222 3/6/2007 Casing/tubing pressure passed  
103-02226 12/12/2012 Other passed  
103-02226 4/17/2007 Casing/tubing pressure passed  
103-02227 12/12/2012 Other passed  
103-02227 7/19/2007 Casing/tubing pressure passed  
103-02228 9/23/2014 Casing/tubing pressure failed  
103-02228 12/5/2012 Other passed  
103-02228 7/2/2007 Casing/tubing pressure passed  
103-02229 12/11/2012 Other passed  
103-02229 7/2/2007 Casing/tubing pressure passed  
103-02327 5/13/2014 Other passed  
103-02327 7/20/2009 Annulus pressure passed  
103-02341 5/14/2014 Other passed  
103-02341 7/8/2009 Casing/tubing pressure passed  
103-02342 8/10/2009 Other passed  
103-02343 9/23/2008 Casing/tubing pressure passed  
103-02344 12/3/2013 Other passed  
103-02344 9/25/2008 Casing/tubing pressure passed  
103-02353 1/7/2010 Other passed  
103-02391 3/12/2013 Annulus method passed  
103-02393 7/21/2014 Casing/tubing pressure passed  
103-02393 8/19/2009 Annulus method passed  
103-02505 3/1/2013 Casing/tubing pressure passed  
103-02505 6/8/2012 Casing/tubing pressure passed  
103-02724 1/13/2014 Other passed  
103-02804 9/10/2013 Annulus method passed  
105-00994 11/19/2014 Annulus method passed  
105-00994 10/12/2009 Casing/tubing pressure passed  
105-00994 8/24/1995 Casing/tubing pressure passed  
107-00616 8/21/2013 Other passed  
107-00616 11/9/2006 Other passed  
107-00616 6/15/1994 Other passed  
107-00649 8/21/2013 Other passed  
107-00649 11/9/2006 Other passed  
107-00649 6/15/1994 Other passed  
107-00655 8/21/2013 Other passed  
107-00655 11/30/2006 Casing/tubing pressure passed pressured backside 150 psi for 30 minutes. No pressure loss.
107-00658 8/21/2013 Other passed  
107-00658 11/9/2006 Casing/tubing pressure failed pressured backside to 150 psi for 30 minutes. No bleed off.
107-00658 8/8/1996 Other passed  
107-00663 8/21/2013 Other passed  
107-00663 11/9/2006 Casing/tubing pressure passed Pressured backside to 150 psi for 30 minutes and bleed off.&
107-00663 8/8/1996 Other passed  
107-00739 3/28/2014 Annulus pressure passed  
107-00739 8/5/2008 Annulus pressure passed  
107-00739 10/22/1993 Casing/tubing pressure passed  
109-00632 11/27/2001 Annulus pressure passed  
109-00980 10/1/2014 Annulus method passed  
109-00980 10/13/1995 Other passed  
109-01093 3/20/2009 None  
109-01093 9/19/1996 Other passed  
109-01433 1/30/2013 Casing/tubing pressure passed  
109-01433 7/25/2005 Casing/tubing pressure passed  
109-02032 1/29/2015 Annulus method passed Well tested at 1710 psig "with no blled off"
109-02032 1/20/2015 Annulus method failed Tested 3x losing ~45 psig/minute, well was then shut-in and emergency cement squeeze was performed, leak was located 2996'-3220', 7.6 bbl of micro matrix was used then drilled out, Inspector Danny Mullins witnessed
109-02032 3/1/2010 Annulus method passed  
109-02032 2/28/2010 Annulus pressure failed  
109-02032 12/1/2006 Annulus method passed  
109-02032 2/9/2003 Monitor record review passed  
109-02703 7/13/2015 Casing/tubing pressure failed MIT failure. Inspector found same pressure on tubing annulus as what was on tubing while injectin fluid. Violation written
109-02703 7/21/2011 Casing/tubing pressure passed  
109-02703 7/31/2006 Casing/tubing pressure passed  

Underground Injection Control Class 2 Wells

Introduction to Class 2 Wells in West Virginia

Collected documents and information for a number of Class 2 disposal wells and secondary recovery area permits

Searchable tables for UIC inspections, UIC permitting and MITs based on a copy of the Office of Oil and Gas' online UIC databases made in 2016.

Select wells which present important issues

A UIC well constructed without any cement behind the steel casing strings to protect groundwater.

A commercial UIC well where activity on the site contaminated groundwater.

A commercial UIC well where activity on the site or because of well failure has contaminated surface water.

A UIC well whose use led to earthquakes in the area.


Gas Well Study is the examination of natural gas wells in West Virginia.

Underground Injection Control Class 2 Wells
These wells are used either for the disposal of oil and gas liquid waste or for the enhanced recovery of oil or natural gas.

Gas Well Study Site Visits
Annual reports, environmental assessments, and individual well information.

YouTube Videos
Select videos from the Gas Well Study YouTube channel.

What Happened at Fernow
An investigation into what caused the vegetation death in the land application area after landspraying hydraulic fracture flowback waste.

The Spill at Buckeye Creek
An investigation into a spill from a Marcellus well site into Buckeye Creek in Doddridge county.


The Details

Plunger Lift Technology on Gas Wells
Fluids Brought to the Surface during Production
Plugging a Well
How To Read a Lab Report
Information the Completion Report Provides
Casing and Cementing